SYMPTOMS The Humax repeatedly re-boots when powering from standby every few seconds, as this can occur for several reasons you can narrow down the possible causes by disconnecting the red power cable between the main board and the Hard Disk drive while the Humax is disconnected from the mains supply, if the Humax then powers up without re-boots, there are only two reported problems that cause this, one is the presents of a corrupted file on the HDD and the other is a failed capacitor that affects the timing of the HDD turn on procedure, this fix details how to locate and replace the faulty capacitor. The faulty component is a 4u7 (4.7 microfarad) electrolytic capacitor and is located on the from edge on the main board (See red ring in picture)

Board.png








Here is a close-up of the faulty capacitor

Old-c.JPG








Here is part of the circuit diagram showing the faulty 4u7 capacitor :-

Diagram.jpg








The fix is to replace this capacitor with a 4u7 with a new one, the replacement does not need to be a surface mounted component, a 25V 4u7 radial capacitor can be used,Here is the board with the old capacitor removed :-

Pad.JPG













Here is the board with the new Radial capacitor installed :-