Difference between revisions of "Firmware Error Codes"

From hummy.tv Wiki
Jump to: navigation, search
Line 1: Line 1:
During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted,The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmare.
+
During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted, The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmware.
  
  
Line 26: Line 26:
 
| E-AC
 
| E-AC
 
| Incorrect Application CRC-32
 
| Incorrect Application CRC-32
| Version Incompatability, See Note 1
+
| Version Incompatibility, See Note 1
 
|-
 
|-
 
| E-ut
 
| E-ut
Line 75: Line 75:
 
This may be displayed for many reasons they include :-
 
This may be displayed for many reasons they include :-
  
* Unexpected system perameters on your Humax unit due to testing of Beta software or incorrect factory settings, Expect to find:- Loader Version = a7.30 or later  System ID = 80BC.7E00  MAC address (first 6 digits) = 000378 or DCD321
+
* Unexpected system parameters on your Humax unit due to testing of Beta software or incorrect factory settings, Expect to find:- Loader Version = a7.30 or later  System ID = 80BC.7E00  MAC address (first 6 digits) = 000378 or DCD321
 
* Corrupted HDF File
 
* Corrupted HDF File
 
* Bad communication to USB device
 
* Bad communication to USB device
Line 84: Line 84:
 
T2 or HD FOX T2), Details for info. only, are as follows :-
 
T2 or HD FOX T2), Details for info. only, are as follows :-
  
*Ensure sotware is in the correct (uncompressed) format  
+
*Ensure software is in the correct (uncompressed) format  
 
*Ensure you are using the correct Download Tool
 
*Ensure you are using the correct Download Tool
 
*Reduce Com. port baud rate and retry
 
*Reduce Com. port baud rate and retry
 
*power cycle the unit
 
*power cycle the unit
 
*Reset the P.C. and retry
 
*Reset the P.C. and retry

Revision as of 01:06, 14 November 2011

During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted, The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmware.


Error Code Displayed Description Explanation / Fix
E-HC/bC Incorrect Header Block (CRC-16) Software Damaged, Retry or Replace
E-dC Incorrect Data Block (CRC-16) Software Damaged, Retry or Replace
E-Hn/bF Invalid HDF Version Incorrect Version, See Note 1
E-Id Invalid System ID Incorrect Version, See Note 1
E-AC Incorrect Application CRC-32 Version Incompatibility, See Note 1
E-ut UART RX/TX Time Out Communications problem (Via Com port) See Note 2
E-Ad Invalid Address HDF File has been incorrectly produced
E-Ao Invalid Offset Address For Upload HDF File has been incorrectly produced
E-Ft Flash Program Time Out Flash Memory Fault, Retry or Replace STB
E-It/Et EEPROM Program Time Out EEPROM Memory Fault, Retry or Replace STB
E-FE Failed Compare After Flash Write Flash Memory Fault, Retry or Replace STB
E-HF Invalid HDF Format HDF File has been incorrectly produced
E-Fn Invalid Flash Devise Flash Memory Fault, Retry or Replace STB
E-AS Incorrect Application Size Incorrect / Corrupted HDF
E-OS Incorrect Operating System Retry after a Set to Factory Default

NOTES

1) Incorrect Version

This may be displayed for many reasons they include :-

  • Unexpected system parameters on your Humax unit due to testing of Beta software or incorrect factory settings, Expect to find:- Loader Version = a7.30 or later System ID = 80BC.7E00 MAC address (first 6 digits) = 000378 or DCD321
  • Corrupted HDF File
  • Bad communication to USB device

2) Communications problem

This error message appears to apply only to software downloaded from a P.C. to the Humax via an RS232 COM. port (not available on HDR FOX T2 or HD FOX T2), Details for info. only, are as follows :-

  • Ensure software is in the correct (uncompressed) format
  • Ensure you are using the correct Download Tool
  • Reduce Com. port baud rate and retry
  • power cycle the unit
  • Reset the P.C. and retry