Difference between revisions of "Firmware Error Codes"
Ezra pound (talk | contribs) |
Ezra pound (talk | contribs) |
||
Line 1: | Line 1: | ||
During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted, The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmware. | During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted, The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmware. | ||
[[File:blank2.jpg|50px|right]] | [[File:blank2.jpg|50px|right]] | ||
− | [[File:error-e-hc.png| | + | [[File:error-e-hc.png|300px|right]] |
{| border="1" | {| border="1" | ||
|- | |- | ||
− | ! width=" | + | ! width="50"|Error Code Displayed |
! width="200"|Description | ! width="200"|Description | ||
− | ! width=" | + | ! width="310"|Explanation / Fix |
|- | |- | ||
| E-HC/bC | | E-HC/bC |
Revision as of 15:04, 26 November 2011
During a software update, where an HDF file on USB stick is presented to a HUMAX unit, The progress of the update is monitored until completion, If an error is detected a code will be displayed on the front panel and the process will be halted, The same codes will be displayed for both Original and Customised firmware, As this is not a function of the Customised Firmware.
Error Code Displayed | Description | Explanation / Fix |
---|---|---|
E-HC/bC | Incorrect Header Block (CRC-16) | Software Damaged, Retry or Replace |
E-dC | Incorrect Data Block (CRC-16) | Software Damaged, Retry or Replace |
E-Hn/bF | Invalid HDF Version | Incorrect Version, See Note 1 |
E-Id | Invalid System ID | Incorrect Version, See Note 1 |
E-AC | Incorrect Application CRC-32 | Version Incompatibility, See Note 1 |
E-ut | UART RX/TX Time Out | Communications problem (Via Com port) See Note 2 |
E-Ad | Invalid Address | HDF File has been incorrectly produced |
E-Ao | Invalid Offset Address For Upload | HDF File has been incorrectly produced |
E-Ft | Flash Program Time Out | Flash Memory Fault, Retry or Replace STB |
E-It/Et | EEPROM Program Time Out | EEPROM Memory Fault, Retry or Replace STB |
E-FE | Failed Compare After Flash Write | Flash Memory Fault, Retry or Replace STB |
E-HF | Invalid HDF Format | HDF File has been incorrectly produced |
E-Fn | Invalid Flash Devise | Flash Memory Fault, Retry or Replace STB |
E-AS | Incorrect Application Size | Incorrect / Corrupted HDF |
E-OS | Incorrect Operating System | Retry after a Set to Factory Default |
NOTES
1) Incorrect Version
This may be displayed for many reasons they include :-
- Unexpected system parameters on your Humax unit due to testing of Beta software or incorrect factory settings, Expect to find:- Loader Version = a7.30 or later System ID = 80BC.7E00 MAC address (first 6 digits) = 000378 or DCD321
- Corrupted HDF File
- Bad communication to USB device
2) Communications problem
This error message appears to apply only to software downloaded from a P.C. to the Humax via an RS232 COM. port (not available on HDR FOX T2 or HD FOX T2), Details for info. only, are as follows :-
- Ensure software is in the correct (uncompressed) format
- Ensure you are using the correct Download Tool
- Reduce Com. port baud rate and retry
- power cycle the unit
- Reset the P.C. and retry