Difference between revisions of "Firmware Error Codes"

From hummy.tv Wiki
Jump to: navigation, search
Line 41: Line 41:
 
| E-Ft
 
| E-Ft
 
| Flash Program Time Out
 
| Flash Program Time Out
| Flash Memory Fault, Retry or Replace
+
| Flash Memory Fault, Retry or Replace STB
 
|-
 
|-
 
| E-It/Et
 
| E-It/Et
 
| EEPROM Program Time Out
 
| EEPROM Program Time Out
| EEPROM Memory Fault, Retry or Replace
+
| EEPROM Memory Fault, Retry or Replace STB
 +
|-
 +
| E-FE
 +
| Failed Compare After Flash Write
 +
| Flash Memory Fault, Retry or Replace STB
 +
|-
 +
| E-HF
 +
| Invalid HDF Format
 +
| HDF File has been incorrectly produced
 +
|-
 +
| E-Fn
 +
| Invalid Flash Devise
 +
| Flash Memory Fault, Retry or Replace STB
 +
|-
 +
| E-AS
 +
| Incorrect Application Size
 +
| Incorrect / Corrupted HDF
 +
|-
 +
| E-OS
 +
| Incorrect Operating System
 +
| Retry after a Set to Factory Default
 
|}
 
|}
 +
 +
'''NOTES'''
 +
 +
'''1) Incorrect Version'''
 +
 +
This may be displayed for a large number of reasons they include :-
 +
* Corrupted HDF File
 +
* Bad communication to USB device
 +
* Unexpected system perameters on your Humax unit due to testing of Beta software or incorrect factory settings
 +
 +
'''2) Communications problem'''
 +
 +
This error message appears to apply only to software downloaded from a P.C. to the Humax via an RS232 COM. port (not available on HDR-FOX-
 +
T2 or HD-FOX-T2), Details for info. only, are as follows :-

Revision as of 16:11, 13 November 2011

THIS PAGE IS UNDER CONSTRUCTION

Error Message Displayed Description Explanation / Fix
E-HC/bC Incorrect Header Block (CRC-16) Software Damaged, Retry or Replace
E-dC Incorrect Data Block (CRC-16) Software Damaged, Retry or Replace
E-Hn/bF Invalid HDF Version Incorrect Version, See Note 1
E-Id Invalid System ID Incorrect Version, See Note 1
E-AC Incorrect Application CRC-32 Version Incompatability
E-ut UART RX/TX Time Out Communications problem (Via Com port) See Note 2
E-Ad Invalid Address HDF File has been incorrectly produced
E-Ao Invalid Offset Address For Upload HDF File has been incorrectly produced
E-Ft Flash Program Time Out Flash Memory Fault, Retry or Replace STB
E-It/Et EEPROM Program Time Out EEPROM Memory Fault, Retry or Replace STB
E-FE Failed Compare After Flash Write Flash Memory Fault, Retry or Replace STB
E-HF Invalid HDF Format HDF File has been incorrectly produced
E-Fn Invalid Flash Devise Flash Memory Fault, Retry or Replace STB
E-AS Incorrect Application Size Incorrect / Corrupted HDF
E-OS Incorrect Operating System Retry after a Set to Factory Default

NOTES

1) Incorrect Version

This may be displayed for a large number of reasons they include :-

  • Corrupted HDF File
  • Bad communication to USB device
  • Unexpected system perameters on your Humax unit due to testing of Beta software or incorrect factory settings

2) Communications problem

This error message appears to apply only to software downloaded from a P.C. to the Humax via an RS232 COM. port (not available on HDR-FOX- T2 or HD-FOX-T2), Details for info. only, are as follows :-